MC388-S1C10-A - Magnetically coded sensor

  • Technical features

    • Basic data
      • SeriesMC388
    • Characteristic parameters
      • Service life20 years, EN ISO 13849-1
      • Mechanical life time10.000.000 actuation cycles
      • CategoryUp to 4, depending on evaluation, 1 sensor connected, EN ISO 13849
      • B10d20.000.000 number of cycles
    • Timing
      • Response time3 ms
    • Electrical equipment
      • Protective circuitShort circuit protected, (Via e.g. MSI-MC310, MSI 100, MSI 200), Current limitation
      • Contact equipment1NC + 1NO
      • Contact typeReed contacts (magnetically sensitive)
      • Requirement on the voltage supply when used acc. to cULus (UL 508)Class 2 Circuits
      • Outputs
        • Max. switching voltage27 V AC/DC
        • Switching current, max.500 mA
    • Connection
      • Number of connections1 Piece(s)
      • Connection 1
        • TypeCable with wire-end sleeves
        • FunctionContact connection
        • Cable length10.000 mm
        • Sheathing materialPVC
        • Cable colorGray
        • Number of conductors4 Piece(s)
    • Mechanical data
      • DesignCube
      • Dimension25 mm x 13 mm x 88 mm
      • Housing materialPlastic, Glass fiber reinforced (PPS), self-extinguishing
      • Net weight572 g
      • Housing colorRed
      • Type of fasteningThrough-hole mounting
      • Installation pointArbitrary, provided housing markings are aligned
      • Switch typeInterlock device without guard interlocking, EN 1088
      • Approach actuation directions3-dimensional
      • External actuatorMagnetically coded
      • Cut-out point (OFF), min.13 mm
      • Assured cut-out distance (Sar), min.30 mm
      • Assured cut-in distance (Sao), max.6 mm
      • Switching tolerance (without ferromagnetic materials in immediate vicinity)-1 ... 1 mm
      • Distance to other magnetic sensors, min.50 mm
      • Approach speed, min.0.05 m/s
    • Environmental data
      • Ambient temperature, operation-20 ... 70 °C
    • Certifications
      • Protection classIP 67
      • CertificationsTÜV Süd, c UL US
      • Test procedure for EMC in accordance with standardEN 60947-5-3, EN 61000-6-3, EN 61000-6-2
      • Test procedure for shock in accordance with standardEN 60947-5-3
      • Test procedure for oscillation in accordance with standardEN 60947-5-3
      • Degree of contaminationEN 60947-1
      • Degree of contamination, external3
    • Functions
      • FunctionsLocking device without guard interlocking in acc. with EN 1088, Integration in control circuits up to category 4 in accordance with EN ISO 13849, Safety system in combination with an evaluation unit such as the MSI-MC310 Safety Relay or the MSI 100 or MSI 200 Safety Controller.
  • Suitable products

  • Accessories

  • Downloads

Part data of: 2013-05-16 21:03:00