MC388-S1C10-A - Magnetically coded sensor


| Part description | MC388-S1C10-A - Magnetically coded sensor |
|---|---|
| Part no. | 63001002 |
-
Technical features
-
Basic data
- SeriesMC388
-
Characteristic parameters
- Service life20 years, EN ISO 13849-1
- Mechanical life time10.000.000 actuation cycles
- CategoryUp to 4, depending on evaluation, 1 sensor connected, EN ISO 13849
- B10d20.000.000 number of cycles
-
Timing
- Response time3 ms
-
Electrical equipment
- Protective circuitShort circuit protected, (Via e.g. MSI-MC310, MSI 100, MSI 200), Current limitation
- Contact equipment1NC + 1NO
- Contact typeReed contacts (magnetically sensitive)
- Requirement on the voltage supply when used acc. to cULus (UL 508)Class 2 Circuits
-
Outputs
- Max. switching voltage27 V AC/DC
- Switching current, max.500 mA
-
Connection
- Number of connections1 Piece(s)
-
Connection 1
- TypeCable with wire-end sleeves
- FunctionContact connection
- Cable length10.000 mm
- Sheathing materialPVC
- Cable colorGray
- Number of conductors4 Piece(s)
-
Mechanical data
- DesignCube
- Dimension25 mm x 13 mm x 88 mm
- Housing materialPlastic, Glass fiber reinforced (PPS), self-extinguishing
- Net weight572 g
- Housing colorRed
- Type of fasteningThrough-hole mounting
- Installation pointArbitrary, provided housing markings are aligned
- Switch typeInterlock device without guard interlocking, EN 1088
- Approach actuation directions3-dimensional
- External actuatorMagnetically coded
- Cut-out point (OFF), min.13 mm
- Assured cut-out distance (Sar), min.30 mm
- Assured cut-in distance (Sao), max.6 mm
- Switching tolerance (without ferromagnetic materials in immediate vicinity)-1 ... 1 mm
- Distance to other magnetic sensors, min.50 mm
- Approach speed, min.0.05 m/s
-
Environmental data
- Ambient temperature, operation-20 ... 70 °C
-
Certifications
- Protection classIP 67
- CertificationsTÜV Süd, c UL US
- Test procedure for EMC in accordance with standardEN 60947-5-3, EN 61000-6-3, EN 61000-6-2
- Test procedure for shock in accordance with standardEN 60947-5-3
- Test procedure for oscillation in accordance with standardEN 60947-5-3
- Degree of contaminationEN 60947-1
- Degree of contamination, external3
-
Functions
- FunctionsLocking device without guard interlocking in acc. with EN 1088, Integration in control circuits up to category 4 in accordance with EN ISO 13849, Safety system in combination with an evaluation unit such as the MSI-MC310 Safety Relay or the MSI 100 or MSI 200 Safety Controller.
-
-
Suitable products
-
Accessories
-
Downloads
-
3D-CAD models (1)
Type Designation Language File size Format 3D-CAD model MC388-S1C10-A Language-independent 26,9 KB zip -
Technical documentation (16)
Type Designation Language File size Format Application information Chinese (simplified) 418 KB pdf Application information German 418 KB pdf Application information English 418 KB pdf Application information French 346,1 KB pdf Application information Italian 418 KB pdf Application information Portuguese 346,1 KB pdf Application information Russian 346,1 KB pdf Application information Spanish 346,1 KB pdf Operating instructions Chinese (simplified) 4,2 MB pdf Operating instructions German 4,1 MB pdf Operating instructions English 4,1 MB pdf Operating instructions French 4,1 MB pdf Operating instructions Italian 4,1 MB pdf Operating instructions Portuguese 4,1 MB pdf Operating instructions Russian 6,5 MB pdf Operating instructions Spanish 4,1 MB pdf -
Certificates (9)
Type Designation Language File size Format Declaration of Conformity Chinese (simplified) 1016 KB pdf Declaration of Conformity German 1,1 MB pdf Declaration of Conformity English 1,1 MB pdf Declaration of Conformity French 1,1 MB pdf Declaration of Conformity Italian 1,1 MB pdf Declaration of Conformity Corean 1016 KB pdf Declaration of Conformity Dutch 1016 KB pdf Declaration of Conformity Portuguese 1,1 MB pdf Declaration of Conformity Spanish 1,1 MB pdf
-
Part data of: 2013-05-16 21:03:00