MSI-RM2

Safety Relays


MSI-RM2 - Safety Relays
CE UL listed cUL listed

Opto-electronic protective devices today frequently have electronic switching outputs and integrated additional functions such as contactor monitoring (EDM) and start/restart interlock. However the requirement for the protective device to transmit the switching signals, not electronically, but rather contact-based to the machine control system often exists.

With the new MSI-RM2 relay module the user is provided with a compact and at the same time cost-effective solution for connecting safety sensors. The relay module, only 17.5 mm wide, has two potential-free make contact circuits with a response time of only 10 ms and LED displays for the switching status.

As its switching behavior is monitored by the EDM function of the safety sensor, an additional electronic monitoring system in the relay module is not required. The MSI‑RM2 is conform to the standard IEC 60204-1.


Special features
  • Suitable up to category 4 (depending on the category of the upstream protective device)

  • Monitoring external contactors in the signal circuit with the upstream protective device

  • 2 release circuits, 1 break contact as signal circuit for device monitoring (EDM)

  • LED displays, K1 and K2

  • Supply voltage through upstream protective device

  • Housing width, 17.5 mm

Important technical data, overview
Category in accordance with EN ISO 13849 Up to 4 (depending on the category of the upstream protective device)
Supply voltage 24 V DC, ±20 % (via AOPD)
Safety-related switching outputs (OSSDs) 2 relay outputs (changeover)
Signal output Relay output (NC)
Response time 10 ms
Temperature range, operation 0...+50 °C
Temperature range, storage -25...+70 ° C
Dimensions (W x H x D) 17.5 mm x 99 mm x 113.6 mm

Functions
  • Signal conversion of electronic outputs of active optoelectronic protective devices on potential-free relay contacts